This manual explains how to use the ARITECH CD34 series for every day use. There is a more detailed manual available for managers which explains how to. 1 Delay Auto Arm L oot on CD34/CDG. D. CD Chirme. A. Bell Test. + +. Tulall the bells. Press. User Menu. Noton ARITECH Advisor MANUAL. Aritech CD34 Panel – posted in Intruder Alarms: Hi everyone I just wondered if anyone can tell me if texecom Impaq glass sensor is compatible.

Author: Daishicage Zulkimuro
Country: Haiti
Language: English (Spanish)
Genre: Medical
Published (Last): 25 February 2016
Pages: 303
PDF File Size: 12.83 Mb
ePub File Size: 1.50 Mb
ISBN: 736-8-26219-517-6
Downloads: 26404
Price: Free* [*Free Regsitration Required]
Uploader: Akinogul

Page of 16 Go. The sensor are two wire types with anti-tamper protection.

Aritech CD34 Panel – Intruder Alarms – Security Warehouse Support Forum

If so, you will not have to press the Accept key. Don’t show me this message again. Ensure that there is a good earth for the alarm system. The use of cable ties is recommended and improves neatness in the box. With the use of a modem messages can be sent from the control panel to a personal computer PCcalled uploading, and from a PC to the control panel, called down loading.

English als bijlage per email. Wij vragen u dus ook te reageren op een antwoord. By removing the JP1.

TOP Related Posts  DHA LAHORE BYLAWS PDF

Everybody involved in installing or maintaining this panel should have access to a copy of this manual. Do not forget to initialise additional keypads and expanders with the menu 5.

Supply only mains power to the control panel. The alarm and tamper are placed together in one zone. If a short circuit should occur, remove the 12 volt connections one by one. Separate alarm and tamper connection Dual loop: Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider. Als er een aritehc wordt gegeven op uw vraag, dan is het voor de gever van het arigech nuttig om te weten als u er wel of niet mee geholpen bent!

Er is een email naar u verstuurd om uw inschrijving definitief te maken. U krijgt dan ook andere vragen en antwoorden te zien.

Handleiding Aritech TD TD (pagina 6 van 32) (English)

If there is a short circuit in the 12 volt power supply, arritech voltage regulators in the supply together with the fuses will prevent serious damage to the system The 12 volt power supply will decrease sharply in the event of a short circuit. Close the tamper switches on the remote keypads, expanders and the control panel. Further SLC BV reserve the right to revise this publication and to make changes from time to time in the contents hereof without the obligation of SLC BV to notify any person of any such revision.

TOP Related Posts  FLORINDA DONNER THE WITCH DREAM PDF

If you enter cs34 wrong code 10 times consecutively, the system is automatically locked for 90 seconds. Maintain a good separation between low voltage and mains supply cables, and use separate points of entry into the control panel cabinet.

The nice way, using the built in communications port and a plug-in. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol.

Aritech TD8803 TD8412

During this time you cannot access the system. Always begin with zero 0 and then enter your code.

U ontvangt de handleiding per email binnen enkele minuten. Keys 9 and 0 have special symbols such as the comma and space.

User Manual for CD Page I didn’t found a suitable plug-in yet. Also close all zones which can cause a direct alarm. Dual loop connection of a detector with latch Note: Any zones that may be open will initiate a full alarm condition and the sounders will activate.

Figure 2 shows how they are connected.